SolarEdge H1300 Power Optimizer for North America
The SolarEdge H1300 is the power optimizer for SolarEdge TerraMax utility-scale inverters. Each optimizer has a single input for two series-connected PV modules and provides module-level MPPT and monitoring. In standby, each optimizer outputs a safety voltage of 1 V.
Specifications
| Item | Value |
|---|---|
| Rated input DC power | 1300 W |
| Connection | Single input for series-connected modules (two PV modules per optimizer) |
| Absolute maximum input voltage (Voc at lowest temperature) | 125 Vdc |
| MPPT operating range | 12.5–105 Vdc |
| Max short-circuit current per input (Isc) | 15 Adc (18.75 Adc adjusted with safety factor) |
| Max efficiency / weighted efficiency | 99.5% / 98.8% |
| Max output current (during operation) | 20 Adc |
| Max output voltage (during operation) | 75 Vdc |
| Safety output voltage (standby) | 1 ± 0.1 Vdc per optimizer |
| Max allowed system voltage | 1500 Vdc |
| Input / output connectors | MC4 |
| Input wire length | 5.25 ft, 5.25 ft (1.6 m, 1.6 m) |
| Output wire length | 0.32 ft, 17.39 ft (0.1 m, 5.3 m) |
| Dimensions (W × L × H) | 5.08 × 6.10 × 2.32 in (129 × 155 × 59 mm) |
| Weight (with cables) | 2.6 lb (1170 g) |
| Protection rating | IP68 / NEMA 6P |
| Operating temperature | -40 to +149 °F (-40 to +65 °C) |
| Compatible inverters | SolarEdge TerraMax SE250KUS, SE285KUS, SE330KUS |
| Safety standards | UL 1741, CSA C22.2#107.1, CSA C22.2#330 |
| Emissions | FCC Part 15 Class A |
| Warranty | 25 years per the SolarEdge datasheet; see SolarEdge’s current warranty terms |
String design limits
| Limit | Value |
|---|---|
| Minimum string length, 400–450 W modules | 27 optimizers (54 modules) |
| Minimum string length, 455–550 W modules | 24 optimizers (48 modules) |
| Minimum string length, 555–650 W modules | 22 optimizers (44 modules) |
| Maximum string length | 40 optimizers (80 modules) |
| Max continuous power per string | 25,000 W |
| Max allowed connected power per string | 33,000 W; lower limits apply with fewer strings, see the datasheet |
| Max difference between shortest and longest string on one inverter | 5 optimizers |
Pricing, availability and ordering
The price shown is CSE Solar USA’s listed price for one optimizer. Utility-scale SolarEdge equipment is confirmed per project: before an order is placed, CSE verifies current availability, lead time and freight to your site. Contact CSE with your project location, quantities and timeline.
Documentation
- SolarEdge H1300 Power Optimizer – datasheet (North America) (SolarEdge Knowledge Center)
Specifications on this page are taken from the SolarEdge datasheet DS-000248-NAM (September 9, 2024). SolarEdge may update its documentation; always design and install to the latest SolarEdge datasheet and installation guide.